Scroll down and click on product names to see full details of each.
Product Code | Description | Size & Measurements (all sizes in mm) | |
---|---|---|---|
212 | Bicortical Dowel | D= 12mm L= 5-25mm | |
214 | Bicortical Dowel | D= 14mm L= 5-25mm | |
216 | Bicortical Dowel | D= 16mm L= 5-25mm | |
218 | Bicortical Dowel | D= 18mm L= 5-25mm |
Source: Ilium
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A bicortical dowel is cylindrical, dense cancellous bone with a cortical face at both ends.
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
130 | Cancellous Block | H≤ 10mm W≤ 10mm L≤ 30mm |
131 | Cancellous Block | H= 11mm W= 11mm L= 30mm |
133 | Cancellous Block | H= 13mm W= 13mm L= 30mm |
135 | Cancellous Block | H= 15mm W= 15mm L= 30mm |
Source: Proximal and distal ends of long bones, calcaneus, and talus
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: Cancellous blocks are cuboid pieces of cancellous bone
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
405 | Cancellous Cervical Block | 5mm x 11mm x 11mm |
406 | Cancellous Cervical Block | 6mm x 11mm x 11mm |
407 | Cancellous Cervical Block | 7mm x 11mm x 11mm |
408 | Cancellous Cervical Block | 8mm x 11mm x 11mm |
409 | Cancellous Cervical Block | 9mm x 11mm x 11mm |
410 | Cancellous Cervical Block | 10mm x 11mm x 11mm |
Source: Distal and proximal ends of the femur and tibia
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: Cancellous cervical blocks are precision milled pieces of cancellous bone
Common Applications: Spinal reconstructions and applications, general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
206 | Cloward Dowel | D= 12mm L= 5-25mm |
207 | Cloward Dowel | D= 14mm L= 5-25mm |
208 | Cloward Dowel | D= 16mm L= 5-25mm |
209 | Cloward Dowel | D= 18mm L= 5-25mm |
Source: Ilium, proximal and distal ends of the tibia and femur
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A cloward dowel is cylindrical, dense cancellous bone with a cortical face on one end
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements(all sizes in mm) |
---|---|---|
200 | Cortical Strut | W< 15mm L= 100-150mm |
201 | Cortical Strut 2-pack | W= 15mm L= 100mm |
202 | Cortical Strut | W= 20mm L= 20mm |
203 | Cortical Strut | W= 20mm L= 40mm |
204 | Cortical Strut | W= 20mm L= 80mm |
205 | Cortical Strut | W= 20mm L= 100mm |
Source: Tibia and femur
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A cortical strut is a long, thin segment of dense cortical bone
Common Applications: Spinal fusions, oral/maxillofacial reconstructions, and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
309 | Unicortical Strip 5-pack | L= 5mm W= 5mm H= 50mm |
310 | Cortical Strip 5-pack | L= 5mm W= 5mm H= 50mm |
311 | Cortical Strip 10-pack | L= 5mm W= 5mm H= 50mm |
Source: Ilium, femur, and tibia
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A cortical/unicortical strip is a segment of bone with either one cortical face and a cancellous base, or all cortical
Common Applications: Spinal fusions, oral/maxillofacial reconstructions, and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
520 | Femur Condyle Whole | Variable (W x L) |
522 | Femur Condyle Hemi | Variable (W x L) |
Source: Femur
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: Femur Condyle, Whole; Femur Condyle, Hemi
Common Applications: General orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
550 | Femur Head | Variable (D) |
Source: Femur
Preservation Method: Frozen, must be stored at -40°C or colder
Details: A femur head is a section of the proximal end of the femur
Common Applications: Hip revisions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
570 | Femur Ring | Variable (H x D) |
Source: Femur
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A femur ring is a cross-section of the femur shaft
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
560 | Femur Shaft Small | Variable (W x L) |
562 | Femur Shaft Large | Variable (W x L) |
564 | Femur Shaft Bisected | Variable (W x L) |
Source: Femur
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: Femur Shaft, Small: Femur Shaft, Large; Femur Shaft, Bisected
Common Applications: General orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
607 | Fibula Ring | Variable (H x D) |
Source: Fibula
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A fibula ring is a cross-section of the fibula shaft
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
604 | Fibula Shaft Small | Variable L≤ 45mm |
605 | Fibula Shaft Large | Variable L≥ 46mm |
606 | Fibula Shaft Bisected | Variable (W x L) |
Source: Fibula
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: Fibula Shaft, Small: Fibula Shaft, Large; Fibula Shaft, Bisected
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
508 | HTO Wedge | H= 8mm |
511 | HTO Wedge | H= 11mm |
516 | HTO Wedge | H= 16mm |
Source: Tibia
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: An HTO wedge is a cross-section of the proximal end of the tibia, with a thick medial edge and a thin lateral edge
Common Applications: Podiatric and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
654 | Humerus Head | Variable (D) |
Source: Humerus
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A humerus head is a section of the proximal end of the humerus
Common Applications: General orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
655 | Humerus Shaft | Variable (W x L) |
Source: Humerus
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A humerus shaft is a section of the humerus between the proximal and distal ends
Common Applications: General orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
303 | Iliac Crest Wedge | H≤ 10mm L W T1 T2 = Variable |
304 | Iliac Crest Wedge | H= 11-13mm L W T1 T2 = Variable |
305 | Iliac Crest Wedge | H= 14-17mm L W T1 T2 = Variable |
306 | Iliac Crest Wedge | H≥ 18mm L W T1 T2 = Variable |
Source: Ilium
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: An iliac crest wedge is a section of the iliac crest including anterior, superior, and posterior cortical faces; with the lateral, medial and inferior faces cut to expose the cancellous core
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
302 | Ilium Tricortical Strip | Variable (L x W x H) |
Source: Ilium
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: An ilium tricortical strip is a section of the iliac crest including anterior, superior, and posterior cortical faces; with the lateral, medial and inferior faces cut to expose the cancellous core
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
590 | Patella Block | Variable (W x L x H) |
Source: Patella
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A patella block is a section of the patella cut medially and laterally to expose the cancellous core
Common Applications: Spinal fusions and general orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
585 | Tibia Shaft Segment | Variable (D x L) |
586 | Tibia Shaft Bisected | Variable (W x L) |
Source: Tibia
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: Tibia Shaft, Segment: Tibia Shaft, Bisected
Common Applications: General orthopaedic reconstructions
Product Code | Description | Size & Measurements (all sizes in mm) |
---|---|---|
587 | Tibia Strut | Variable (W x L) |
Source: Tibia
Preservation Method: Lyophilized, must be stored at ambient temperature
Details: A tibia strut is a flat plate of cortical bone from the tibial shaft
Common Applications: General orthopaedic reconstructions